UPO1000CS Series
UPO1000CS Series
UPO1000CS series is a multi-function, cost-effective digital phosphor oscilloscope. It can be widely used in the fields of electronic and electrical design, debugging, education and industrial design. UPO1000CS series adopts parallel digital signal processing technology, which greatly improves the data processing speed and waveform capture rate. The original Ultra Phosphor technology can present the cumulative effect of the tested signal as a multi-layered afterglow. Compared with traditional digital storage oscilloscopes, the persistence of digital phosphor oscilloscopes can present three-dimensional waveform data of amplitude, time and signal intensity. Fast Acquire technology can accurately capture abnormal events such as video, jitter, noise and runt signals.
100MHz~200MHz
BANDWIDTH
2
ANALOG CHANNELS
1GSa/s
REAL-TIME SAMPLE RATE
56Mpts
MAX. MEMORY DEPTH
500,000wfms/s
WAVEFORM CAPTURE RATE
/
DIGITAL CHANNELS
FEATURES
MODEL
MANUAL
OPTIONS&ACCESSORIES
SOFTWARE&FIRMWARE
VIDEO
FAQS
Web Control
The oscilloscope can be connected and remotely controlled via the web page. Support PC and mobile phone dual platform operation. This eliminates the need to install local programs, saving space and time.
Web Control
256 gray level display
The original Ultra Phosphor display technology is easy to obtain more waveform information and detailed observation.
256 gray level display
Ultra high capture rate
UPO1000CS series adopts innovative digital signal parallel processing technology. It has a very high capture rate in its peer products. Effectively reduce signal loss and help you better capture abnormal signals.
Ultra high capture rate
Deep memory depth
UPO1000CS series 56M sampling points per channel. This enables the oscilloscope to maintain high sampling rate in a wider time base range, At the same time considering the whole and details of the waveform, which greatly improves the ability to capture abnormal waveforms.
Deep memory depth
Serial bus trigger and hardware decoding
Innovative hardware decoding realizes real-time decoding. The decoding speed with deep storage 56Mpts realizes the millisecond level, which solves the problem of long-time waiting for viewing decoded data. The decoding will not affect the refresh speed of the waveform, and the waveform has the effect of digital fluorescence display. The event list can display the decoded data with deep storage and the time of the packet. These improved technologies will help you better test the serial bus.
Serial bus trigger and hardware decoding
Multi-Scopes
Signals with different clock sources and large frequency difference can also display the waveform stably on the screen, which is convenient for customers to analyze the waveform parameters.
Multi-Scopes
1Mpts FFT sampling point
UPO1000CS series has 1Mpts FFT sampling points. It can also set the practical functions of spectrum analyzer such as frequency range, detection mode and spectrum marking. It is convenient for you to analyze the signal in frequency domain on oscilloscope.
1Mpts FFT sampling point
MODEL
UPO1102CS
BANDWIDTH:100MHz
ANALOG CHANNELS:2
REAL-TIME SAMPLE RATE:1GSa/s
MAX. MEMORY DEPTH:56Mpts
WAVEFORM CAPTURE RATE:500,000wfms/s
DIGITAL CHANNELS:/
WAVEFORM GENERATOR:/
UPO1202CS
BANDWIDTH:200MHz
ANALOG CHANNELS:2
REAL-TIME SAMPLE RATE:1GSa/s
MAX. MEMORY DEPTH:56Mpts
WAVEFORM CAPTURE RATE:500,000wfms/s
DIGITAL CHANNELS:/
WAVEFORM GENERATOR:/
DATASHEETS
download UPO1000CS Datasheet EN
Version:V1.0
Release Date:2024.05.14
QUICK GUIDE
download UPO1000CS Quick guide EN
Version:V1.0
Release Date:2023.10.23
USER MANUAL
download UPO1000CS User's Guide EN
Version:V1.0
Release Date:2023.10.23
PROGRAMMING MANUAL
download UPO1000CS Programming Manual EN
Version:V1.0
Release Date:2023.10.23
SERVICE MANUAL
OPTIONS
UPO1000CS-AUTO
Description:Auto serial bus trigger and analysis (CAN, LIN) for UPO1000CS series
ACCESSORIES
UT-P06
download UT-P06
Description:Passive probe ratio:(10X:1X),300MHz
UT-P05
download UT-P05
Description:Passive probe:(10X:1X),200MHz
UT-P20
download UT-P20
Description:High voltage probe ratio:100X:1X,250MHz,1.5KV
UT-P07
download UT-P07
Description:Passive probe ratio:10X:1X,500MHz
UT-P21
download UT-P21
Description:High voltage probe ratio:1000X:1X, 50MHz,DC:10KV,AC:7KV
UT-P30
download UT-P30
Description:Differential probe:100MHz, ±800Vpp
UT-P31
download UT-P31
Description:High voltage differential probe:100MHz, ±1.5KV
UT-P32
download UT-P32
Description:High voltage differential probe:50MHz,±3.0KV
UT-P33
download UT-P33
Description:High voltage differential probe:120MHz,±14KV
UT-V23
download UT-V23
Description:High voltage probe ratio:100X:1X,100MHz,2.0KV
UT-P40
download UT-P40
Description:Current probe:DC~100kHz,60A
UT-P41
download UT-P41
Description:Current probe:DC~100kHz,100A
UT-P43
download UT-P43
Description:Current probe:DC~25MHz,20A:AC/DC
UT-P44
download UT-P44
Description:Current probe:DC~50MHz,40A:AC/DC
UT-P04
download UT-P04
Description:Passive probe:(10X:1X),100MHz
UT-P03
download UT-P03
Description:Passive probe:(10X:1X),60MHz
UT-P01
download UT-P01
Description:Passive probe:(10X:1X),25MHz
UT-P08A
download UT-P08A
Description:Passive probe:(10X:1X),350MHz
UT-P42
download UT-P42
Description:Current probe:DC~150kHz,200A
UT-P35
download UT-P35
Description:High-Voltage Differential Probes,50MHz,7ns,2%
UT-P36
download UT-P36
Description:High-Voltage Differential Probes,50MHz,3.5ns,2%
UT-P4100A
download UT-P4100A
Description:100A/600kHz Low frequency current probe<br>Range:100A/10A<br>Freq range:DC~600kHz<br>Rise time:≤583ns
UT-P4030D
download UT-P4030D
Description:30A/ DC~100MHz High frequency current probe<br>Range:30A/5A<br>Freq range:DC~100MHz<br>Rise time:≤3.5ns
UT-P07A
download UT-P07A
Description:Passive probe ratio:10X,10MΩ,500MHz,600Vpk
UT-P4150
download UT-P4150
Description:150A/ DC-12MHz High frequency current probe<br>Range:150A/30A<br>Freq range:DC~12MHz<br>Rise time:≤29ns
UT-P4500
download UT-P4500
Description:500A/ DC~5MHz High frequency current probe<br>Range:500A/75A<br>Freq range:DC~5MHz<br>Rise time:≤70ns
UT-P4100B
download UT-P4100B
Description:100A/2MHz Low frequency current probe<br>Range:100A/10A<br>Freq range:DC~2MHz<br>Rise time:≤175ns
SOFTWARE
UPO1000CS Software
Version: V2.4
2024/05/09
FIRMWARE
UPO1000CS Firmware
Version: V1.05.0051
2023/07/24
Release notes
FAQs
Release notes